LUXURY HIGH-END WINDOW & DOOR MANUFACTURER AND GLOBAL SUPPLIER

Extra-Large Fixed Window 100P/116/120 China Manufacturer: Glass and Quote Specifications

Review verified RGNL 100P/116/120 extra-large fixed window frame, glass and white finish options, plus quotation inputs for project sourcing from China.
Extra-large white aluminum fixed window installed in a bright contemporary villa living room
Verified Product Specification

Extra-Large Fixed Window 100P/116/120 China Manufacturer: Glass and Quote Specifications

Verified frame, glass and finish information for developers, architects, contractors and importers preparing a project quotation for large fixed aluminum glazing from China.

Extra-large white aluminum fixed window installed in a bright contemporary villa living room
Illustrative application scene for an extra-large white aluminum fixed window. Final frame, glass, divisions and installation details depend on the approved project specification.
6063-T5Catalog-listed aluminum profile
1.4-2.0 mmListed profile thickness range
8 frame depths60-120 mm options listed
3 glass buildsDouble, laminated and triple IGU options

What the Catalog Confirms

Rogenilan’s 2024 catalog identifies an Extra Large Fixed Window 100P/116/120. The fixed lite has no operable sash, making the glass area, frame selection, divisions, supporting structure and installation interface the main quotation decisions.

Buyers can review the Picture Windows category and the official RGNL-100P Series product page. The product page provides base 100P series information; the fixed-window configuration and values below are taken from the catalog’s dedicated fixed-window page.

Verified Extra-Large Fixed Window Specifications

Item Catalog information Buyer check
Product Extra Large Fixed Window 100P/116/120 Identify the selected series on every elevation.
Operation Fixed, non-operable lite Mark adjacent operable units separately.
Frame dimensions 60, 70, 76, 93, 100, 110, 116 and 120 mm Do not select depth by appearance alone; request the proposed section.
Profile 6063-T5 aluminum Confirm material documentation required by the project.
Profile thickness 1.4-2.0 mm, multiple options Confirm the exact thickness for the quoted frame and opening.
Double insulating glass 5 mm + 15A + 5 mm Confirm treatment, spacer and project safety requirements.
Laminated insulating glass 5 mm + 1.14 PVB + 5 mm + 12A + 5 mm Confirm laminated side, heat treatment and edge details.
Triple insulating glass 5 mm + 12A + 5 mm + 12A + 5 mm Confirm overall weight and compatibility with the proposed frame.
Glass slot and positioning gap Multiple options; no single value stated Request a section drawing for the selected glass build-up.
White finish Flange White is listed as a powder-coating color Approve a physical color and gloss sample before production.
The catalog page also prints performance values, but the applicable test standards and reports are not identified. This article therefore does not present those values as verified project performance.

Fixed-Window Configuration Decisions

Single Fixed Lite

A single uninterrupted glazed area provides the simplest elevation. Send the exact width and height so the manufacturer can review the frame and glass configuration.

Divided Fixed Assembly

Mullions or transoms may divide a large elevation. Show every division and sightline rather than asking the factory to choose the layout.

Fixed Plus Operable Units

If the elevation includes casement, awning or other opening units, schedule them separately and coordinate frame depths, color and glass appearance.

White Frame Coordination

The catalog lists Flange White powder coating. State the required color reference, gloss, interior/exterior color and sample approval process.

Glass Selection and Approval

The three catalog-listed glass build-ups provide quotation starting points, not automatic approval for every opening. For an extra-large fixed window, send the project location, opening dimensions, building height and required standards so the proposed glass can be reviewed for the actual application.

Ask the quotation to identify each pane thickness, cavity, PVB layer, heat treatment, coating, spacer, gas fill if applicable, safety marking and edge treatment. If thermal, acoustic, wind, water or impact performance is required, request evidence that applies to the complete proposed window rather than glass-only data.

What Changes the Project Price

Price depends on the defined configuration. Compare quotations only when frame depth, profile thickness, glass, finish, divisions, accessories, packing and delivery scope are the same.

  • Overall width, height and quantity
  • Selected 100P, 116 or 120 series
  • Frame depth and profile thickness
  • Glass build-up and treatment
  • Mullion and transom divisions
  • White coating reference and gloss
  • Perimeter trims and anchors
  • Required reports and drawings
  • Export crate and glass protection
  • Destination and Incoterm

Information to Send for a Factory Quote

Send a dimensioned window schedule, elevations and wall sections. Identify rough opening, finished unit size, sill level, frame depth constraints, every fixed division and any adjacent operable window or door.

  • Project location and building type
  • Opening size and quantity schedule
  • Interior and exterior elevations
  • Selected or preferred frame series
  • Required glass specification
  • Safety and performance standards
  • White color and finish sample
  • Wall, sill and drainage details
  • Packaging and site handling limits
  • Delivery destination and Incoterm

FAQ

Is this a picture window or a fixed window?

The catalog names the product an Extra Large Fixed Window. In project schedules, picture window commonly describes a large non-operable glazed window; use the manufacturer’s exact product description in the quotation.

Which frame depths are listed?

The catalog lists 60, 70, 76, 93, 100, 110, 116 and 120 mm. The supplier should confirm the proposed depth and section for the actual opening and glass.

Is a white frame available?

Yes. Flange White is listed as a powder-coating color. Request a physical sample because color name, gloss and production tolerance must be approved for the order.

Which glass build-ups are listed?

The catalog lists 5 mm + 15A + 5 mm double insulating glass, a laminated insulating build-up of 5 mm + 1.14 PVB + 5 mm + 12A + 5 mm, and 5 mm + 12A + 5 mm + 12A + 5 mm triple insulating glass.

Can the catalog performance icons be used for project approval?

Not by themselves. Request the applicable standard, report, tested size and configuration before using any performance value in a project submittal.

Request an Extra-Large Fixed Window Quote

Send Rogenilan the elevation, unit sizes, frame preference, glass requirement, white finish reference, documentation needs and delivery destination. The factory can review a defined configuration before preparing the quotation.

Search Result