RGNL-120 Electric Horizontal Window China Manufacturer Quote
For overseas project buyers, a useful quote must define the window geometry, electric opening method, glass build-up, finish, controls and delivery scope. The verified RGNL-120 system provides a factual starting point for that RFQ.

Direct Answer for China Sourcing
The RGNL-120 Narrow-frame Electric Horizontal Window is listed with a 120 mm thermal-break frame, 6060-T6 aluminum profile, 2.0 mm profile thickness and electric opening. The Rogenilan catalog also identifies an electric flat-push motor, control panel and remote-control opening for this system.
Before requesting a manufacturer quote, define the opening elevation, unit sizes, operable vent positions, power and control requirements, glass build-up, finish, quantity and destination. These inputs determine whether returned quotations describe the same product.
Verified RGNL-120 Quick Specs
| Specification | Verified Listing | Buyer Action |
|---|---|---|
| System | 120 thermal-break narrow-frame manual/electric horizontal pushing window | Confirm the required operating configuration on the elevation. |
| Frame and profile | 120 mm frame; 6060-T6 aluminum; 2.0 mm profile thickness | Match each quoted unit to the approved system and size schedule. |
| Double glazing | 5 mm + 15A + 5 mm tempered insulating glass | Confirm coating, spacer, safety treatment and applicable project standard. |
| Laminated insulating option | 5 mm + 1.14 PVB + 5 mm + 12A + 5 mm | State which openings require laminated glass. |
| Triple glazing option | 5 mm + 12A + 5 mm + 12A + 5 mm | Request feasibility confirmation for the scheduled unit sizes. |
| Glass slot | 40 mm | Check the selected glass build-up against the system allowance. |
| Hardware and operation | WEHAG system hardware; electric opening is listed on the product page | Define motor, controls, remote functions and any required manual operation. |
| Surface options | Powder coating, anodized, wood-grain and PVDF finishes are listed | Approve the exact color and finish sample before production. |
Configure the Electric Opening Before Pricing
Window Elevation
Mark every fixed and operable section. A visual showing the location and opening direction of each narrow vent prevents a factory from pricing a different arrangement.
Motor and Controls
State the power supply, control-panel location and remote-control requirement. Ask the manufacturer to identify what is included in the unit price.
Glass Schedule
Select one verified glass build-up or submit the project requirement for confirmation. Do not accept a quotation that says only “double glass.”
Interface Details
Provide wall build-up, sill, drainage, interior finish and access requirements so installation interfaces and service access can be reviewed.
Selection Logic for Project Buyers
Use the electric configuration where remote or centralized opening is part of the design brief. The buyer should confirm how the operable sections interact with curtains, screens, furniture and exterior obstructions. For repeated hotel, apartment or commercial openings, assign a unique window mark to every size and control group.
The Intelligent/Electric Windows category shows the related Rogenilan product range. Keep the RGNL-120 product link in the RFQ so the requested system cannot be confused with a vertical lifting window.
Quote and Price Factors
Project pricing depends on the confirmed unit schedule and scope, not only window area. Compare quotations against the same inputs:
- Unit width, height and quantity
- Fixed and operable panel arrangement
- Electric motor and control package
- Remote-control quantity and grouping
- Selected glass build-up
- Frame color and surface treatment
- Hardware and accessory scope
- Screens, trims and installation parts
- Packaging and unit-marking method
- Destination and requested Incoterm
RFQ Information to Send the Manufacturer
Send one controlled package containing the project location, architectural elevations, opening schedule, quantity by mark, interior and exterior views, glass specification, frame finish, motor and control brief, power information, screen requirements, installation details, destination and target delivery date.
Ask the returned quotation to identify included components, excluded work, drawing-approval stages, packaging basis and required technical documents. This creates a comparable commercial response without assuming unverified lead times, performance values or certification.
FAQ
What opening information is needed for an RGNL-120 quote?
Provide each unit’s width, height, quantity, fixed and operable sections, opening direction and installation interface. Add a marked elevation where several windows share one facade.
Which glass options are verified for this system?
The catalog lists 5 mm + 15A + 5 mm double glazing, a laminated insulating configuration of 5 mm + 1.14 PVB + 5 mm + 12A + 5 mm, and triple glazing of 5 mm + 12A + 5 mm + 12A + 5 mm. Final use must follow the approved order.
Does the quote automatically include the motor and controls?
Do not assume it does. The sources list electric opening, an electric flat-push motor, a control panel and remote control, but the quotation should state the exact included control package and quantities.
Can performance values be specified from the catalog alone?
No. Submit the project’s required standard and performance criteria, then request documents applicable to the proposed configuration. Unverified header values are not used in this article.
Request an RGNL-120 Project Quote
Send Rogenilan the window schedule, drawings, quantities, glass, finish, motor-control brief and delivery destination. The quotation can then be prepared against a defined electric horizontal window configuration.